Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
2.
Korean Journal of Radiology ; : 1422-1430, 2019.
Article in English | WPRIM | ID: wpr-760253

ABSTRACT

OBJECTIVE: To explore whether computed tomography (CT) pulmonary vascular volume ratio can be used to evaluate the effectiveness of pulmonary artery angioplasty in patients with peripheral pulmonary artery stenosis. MATERIALS AND METHODS: Changes in CT pulmonary vascular volume ratio between serial cardiothoracic CT examinations were calculated in 38 patients. Fifteen patients underwent interim pulmonary artery angioplasty (group 1), while 23 did not (group 2). According to the effectiveness of pulmonary artery angioplasty, patients in group 1 were further divided into group 1A (improved or aggravated) and group 1B (ineffective). Changes in the pulmonary vascular volume percentages among the three groups (group 1A, group 1B, and group 2) on serial CT examinations were compared. RESULTS: Pulmonary artery angioplasty on serial CT examinations was successful in seven patients, ineffective in seven patients, and aggravated in one patient. As a result, eight patients were included in group 1A and seven were included in group 1B. Changes in the CT pulmonary vascular volume percentages in group 1A were statistically significantly greater than those in group 1B (11.6 ± 5.6% vs. 2.7 ± 1.6%, p 0.1). CONCLUSION: CT pulmonary vascular volume ratio can be used to evaluate the effectiveness of pulmonary artery angioplasty in patients with peripheral pulmonary artery stenosis.


Subject(s)
Humans , Angioplasty , Constriction, Pathologic , Heart Defects, Congenital , Pulmonary Artery
3.
Korean Journal of Radiology ; : 23-31, 2018.
Article in English | WPRIM | ID: wpr-741389

ABSTRACT

OBJECTIVE: To compare radiation doses between conventional and chest pain protocols using dual-source retrospectively electrocardiography (ECG)-gated cardiothoracic computed tomography (CT) in children and adults and assess the effect of tube current saturation on radiation dose reduction. MATERIALS AND METHODS: This study included 104 patients (16.6 ± 7.7 years, range 5–48 years) that were divided into two groups: those with and those without tube current saturation. The estimated radiation doses of retrospectively ECG-gated spiral cardiothoracic CT were compared between conventional, uniphasic, and biphasic chest pain protocols acquired with the same imaging parameters in the same patients by using paired t tests. Dose reduction percentages, patient ages, volume CT dose index values, and tube current time products per rotation were compared between the two groups by using unpaired t tests. A p value 0.05); the groups with tube current saturation showed significantly higher volume CT dose index values (p < 0.01) and tube current time product per rotation (p < 0.001) than the groups without tube current saturation in all protocols. CONCLUSION: The radiation dose of dual-source retrospectively ECG-gated spiral cardiothoracic CT can be reduced by approximately 15% by using the biphasic chest pain protocol instead of the conventional protocol in children and adults if radiation dose parameters are further optimized to avoid tube current saturation.


Subject(s)
Adult , Child , Humans , Chest Pain , Cone-Beam Computed Tomography , Electrocardiography , Methods , Retrospective Studies , Thorax
4.
Korean Journal of Radiology ; : 1031-1041, 2018.
Article in English | WPRIM | ID: wpr-719137

ABSTRACT

OBJECTIVE: To compare image quality and radiation dose of high-pitch dual-source spiral cardiothoracic computed tomography (CT) between non-electrocardiography (ECG)-synchronized and prospectively ECG-triggered data acquisitions in young children with congenital heart disease. MATERIALS AND METHODS: Eighty-six children (≤ 3 years) with congenital heart disease who underwent high-pitch dual-source spiral cardiothoracic CT were included in this retrospective study. They were divided into two groups (n = 43 for each; group 1 with non-ECG-synchronization and group 2 with prospective ECG triggering). Patient-related parameters, radiation dose, and image quality were compared between the two groups. RESULTS: There were no significant differences in patient-related parameters including age, cross-sectional area, body density, and water-equivalent area between the two groups (p > 0.05). Regarding radiation dose parameters, only volume CT dose index values were significantly different between group 1 (1.13 ± 0.09 mGy) and group 2 (1.07 ± 0.12 mGy, p 0.05). CONCLUSION: In high-pitch dual-source spiral pediatric cardiothoracic CT, additional ECG triggering does not substantially reduce motion artifacts in young children with congenital heart disease.


Subject(s)
Child , Humans , Aorta , Artifacts , Cone-Beam Computed Tomography , Coronary Vessels , Diaphragm , Electrocardiography , Heart Defects, Congenital , Lung , Noise , Prospective Studies , Retrospective Studies , Signal-To-Noise Ratio , Thoracic Wall
SELECTION OF CITATIONS
SEARCH DETAIL